← All productsFan drives · STG line

STG DRV

Command the fan through the STG network or the local interface. Installed next to the fan or the ventilation box: relay for on/off, 0–10 V output for speed.

STG DRV, fan drive interface
Switches1 × 10 A relayAC fan on/off, according to the equipment
Modulates1 × 0–10 V outputproportional speed of an EC fan
ReceivesSTG wireless networkcommands from MINI, QAI, CPD or controller
OperatesLocal interfaceon/off and speed, even without the network
How it works

Two command modes, one device.

The DRV is the bridge between the STG network and the ventilation equipment. It sits next to the fan and executes the command, with no dedicated signal cable.

Mode 01

Local command

On/off and speed set on the DRV's own interface. Works without the network.

STG DRV
STG DRV(AC via relay · EC via 0–10 V)
relay · 0–10 V
Wave fanVentilation box
Fan or boxSingle-phase AC or EC, as configured
Mode 02

Command over the STG network

Receives commands from the STG network and drives the fan. The MINI or QAI reads the room and sends the command wirelessly; the DRV executes it at the equipment.

STG MINISTG QAI
STG MINI or STG QAIroom reading and command source
STG wireless network
STG DRV
STG DRV(AC via relay · EC via 0–10 V)
relay · 0–10 V
Wave fanVentilation box
Fan or boxSingle-phase AC or EC, as configured

Several sensors can command the same DRV through the configured rule. Drive selection depends on the motor and the project configuration; the DRV handles single-phase AC or EC fans.

Retrofit with less cablingNo control cable between sensor and fan: less installation time and cost.
Proportional or on/offFine EC fan speed through the 0–10 V output; AC on/off through the 10 A relay.
Independent local operationThe equipment can be operated from the DRV interface even without the network.
Technical data

Product specifications.

Output limits and compatibility with the driven fan are confirmed by engineering in the quote.

Analogue output
1 × 0–10 V, proportional speed control (EC fan)
Digital output
1 × 10 A relay, on/off (AC fan, according to the equipment)
Fans
Single-phase AC or EC, according to the project configuration
Command
Local, on the DRV interface · over the STG wireless network, from MINI, QAI, CPD or controller
Version
Single, ready to integrate into the ventilation system
Location
Next to the fan or the ventilation box

STG DRV in your project?

Tell us the fan (AC or EC, single-phase) and the sensor or controller that will command it. Engineering confirms the configuration and returns the proposal.